Repairing of Envicrete Façade Tiles & Corner Stones - A Level Block and Sci Block Inner Court yard
Hrs/Qty | Service | Rate/Price | Adjust | Sub Total |
---|---|---|---|---|
125 Pair | Removing of only loose corner stones with care by using hammer and chisel and reuse it after cleaning of necessary material. Surface to be prepared before laying of corner stone by proper tucking & laying of corner stones ( as per sample installed at site) with base plaster of 1:4 minimum 1/2"",3/4"" thickness(Lucky or Falcon cement to be used) upto required depth with SBR(Zahabiya,fospak,Ultrachemical or approved brand) as standard ratio 1 part of water and 4 part of cement by volume, leveled with existing cladding tile with cleaning and grouting of (match color )and use of z shape shuttering Patti for proper fixing of stones with wall on each stones including installation of pipe scaffolding upto required height.Complete in all respect as directed by Engineer. Approximate size 15"x 0'-7.5" |
Rs. 0.00 | 0.00% | Rs. 0.00 |
125 Pair | Removing of only loose corner stones with care by using hammer and chisel and reuse it after cleaning of necessary material. Surface to be prepared before laying of corner stone by proper tucking & laying of corner stones ( as per sample installed at site) with base plaster of 1:4 minimum 1/2"",3/4"" thickness(Lucky or Falcon cement to be used) upto required depth with SBR(Zahabiya,fospak,Ultrachemical or approved brand) as standard ratio 1 part of water and 4 part of cement by volume, leveled with existing cladding tile with cleaning and grouting of (match color )and use of z shape shuttering Patti for proper fixing of stones with wall on each stones including installation of pipe scaffolding upto required height.Complete in all respect as directed by Engineer. Approximate size 0'-0.7.5"x 0'-7.5" |
Rs. 0.00 | 0.00% | Rs. 0.00 |
25 Pair | Removing of only loose corner stones with care by using hammer and chisel and reuse it after cleaning of necessary material. Surface to be prepared before laying of corner stone by proper tucking & laying of corner stones ( as per sample installed at site) with base plaster of 1:4 minimum 1/2"",3/4"" thickness(Lucky or Falcon cement to be used) upto required depth with SBR(Zahabiya,fospak,Ultrachemical or approved brand) as standard ratio 1 part of water and 4 part of cement by volume, leveled with existing cladding tile with cleaning and grouting of (match color )and use of z shape shuttering Patti for proper fixing of stones with wall on each stones including installation of pipe scaffolding upto required height. Complete in all respect as directed by Engineer. Approximate size 15"x 0'-7.5" |
Rs. 0.00 | 0.00% | Rs. 0.00 |
25 Pair | Removing of only loose corner stones with care by using hammer and chisel and reuse it after cleaning of necessary material. Surface to be prepared before laying of corner stone by proper tucking & laying of corner stones ( as per sample installed at site) with base plaster of 1:4 minimum 1/2"",3/4"" thickness(Lucky or Falcon cement to be used) upto required depth with SBR(Zahabiya,fospak,Ultrachemical or approved brand) as standard ratio 1 part of water and 4 part of cement by volume, leveled with existing cladding tile with cleaning and grouting of (match color )and use of z shape shuttering Patti for proper fixing of stones with wall on each stones including installation of pipe scaffolding upto required height.Complete in all respect as directed by Engineer. Approximate size 0'-0.7.5"x 0'-7.5" |
Rs. 0.00 | 0.00% | Rs. 0.00 |
1 Pair | Removing of only loose corner stones with care by using hammer and chisel and reuse it after cleaning of necessary material. Surface to be prepared before laying of corner stone by proper tucking & laying of corner stones ( as per sample installed at site) with base plaster of 1:4 minimum 1/2"",3/4"" thickness(Lucky or Falcon cement to be used) upto required depth with SBR(Zahabiya,fospak,Ultrachemical or approved brand) as standard ratio 1 part of water and 4 part of cement by volume, leveled with existing cladding tile with cleaning and grouting of (match color )and use of z shape shuttering Patti for proper fixing of stones with wall on each stones including installation of pipe scaffolding upto required height.Complete in all respect as directed by Engineer. Approximate size 15"x 0'-7.5" |
Rs. 0.00 | 0.00% | Rs. 0.00 |
1 pair | Removing of only loose corner stones with care by using hammer and chisel and reuse it after cleaning of necessary material. Surface to be prepared before laying of corner stone by proper tucking & laying of corner stones ( as per sample installed at site) with base plaster of 1:4 minimum 1/2"",3/4"" thickness(Lucky or Falcon cement to be used) upto required depth with SBR(Zahabiya,fospak,Ultrachemical or approved brand) as standard ratio 1 part of water and 4 part of cement by volume, leveled with existing cladding tile with cleaning and grouting of (match color )and use of z shape shuttering Patti for proper fixing of stones with wall on each stones including installation of pipe scaffolding upto required height.Complete in all respect as directed by Engineer. Approximate size 0'-0.7.5"x 0'-7.5" |
Rs. 0.00 | 0.00% | Rs. 0.00 |
2000 Sqf | Removing of only loose Envicrete cladding tiles and coping with care by using hammer and chisel and reuse it after cleaning of necessary material. Surface to be prepared before laying of cladding tiles and copping by proper tucking & Laying of envicrete cladding tiles with base plaster of 1:4 ratio minimum 1/2"",3/4"" thickness(Lucky or Falcon cement to be used)unto required depth with SBR(zahabiya,fospak,Ultrachemical or approved brand) as standard ratio 1 part of water and 4 part of cement by volume , leveled with existing cladding tile with cleaning and grouting of (match color) and use of z shape shuttering Patti for proper fixing of cladding tiles with wall on each tiles including installation of pipe scaffolding upto required height. Complete in all respect as directed by Engineer. (Envicrete cladding will be provided by KGS if required) A' Level |
Rs. 0.00 | 0.00% | Rs. 0.00 |
750 Sqft | Removing of only loose Envicrete cladding tiles and coping with care by using hammer and chisel and reuse it after cleaning of necessary material. Surface to be prepared before laying of cladding tiles and copping by proper tucking & Laying of envicrete cladding tiles with base plaster of 1:4 ratio minimum 1/2"",3/4"" thickness(Lucky or Falcon cement to be used)unto required depth with SBR(zahabiya,fospak,Ultrachemical or approved brand) as standard ratio 1 part of water and 4 part of cement by volume , leveled with existing cladding tile with cleaning and grouting of (match color) and use of z shape shuttering Patti for proper fixing of cladding tiles with wall on each tiles including installation of pipe scaffolding upto required height. Complete in all respect as directed by Engineer. (Envicrete cladding will be provided by KGS if required) Science block |
Rs. 0.00 | 0.00% | Rs. 0.00 |
2 nos | Repairing of window projections including apply zuba 16/123 anti rust on exposed rusted steel bars after removal of rust using steel wire brush, fixing of chicken wire mesh where required, apply 1:4 cement sand mortar of required depth to match existing thickness or any chemical required to secure projections complete. Approximate size: 9'-6"x2'-0"x0'-7.5" thick ( 1st & 2nd Floor)A'Level |
Rs. 0.00 | 0.00% | Rs. 0.00 |
1 nos | Repairing of window projections including apply zuba 16/123 anti rust on exposed rusted steel bars after removal of rust using steel wire brush, fixing of chicken wire mesh where required, apply 1:4 cement sand mortar of required depth to match existing thickness or any chemical required to secure projections complete. Approximate size: 8'-6"x2'-0"x0'-7.5" thick (1st Floor)A'Level |
Rs. 0.00 | 0.00% | Rs. 0.00 |
1 nos | Repairing of window projections including apply zuba 16/123 anti rust on exposed rusted steel bars after removal of rust using steel wire brush, fixing of chicken wire mesh where required, apply 1:4 cement sand mortar of required depth to match existing thickness or any chemical required to secure projections complete. Approximate size: 4'-6"x2'-0"x0'-7.5" thick (1st Floor) A'Level |
Rs. 0.00 | 0.00% | Rs. 0.00 |
1 nos | Repairing of window projections including apply zuba 16/123 anti rust on exposed rusted steel bars after removal of rust using steel wire brush, fixing of chicken wire mesh where required, apply 1:4 cement sand mortar of required depth to match existing thickness or any chemical required to secure projections complete. Approximate size: 10'-6"x2'-6"x0'-7.5" thick(2nd Floor)A'Level |
Rs. 0.00 | 0.00% | Rs. 0.00 |
4 nos | Repairing of window projections including apply zuba 16/123 anti rust on exposed rusted steel bars after removal of rust using steel wire brush, fixing of chicken wire mesh where required, apply 1:4 cement sand mortar of required depth to match existing thickness or any chemical required to secure projections complete. Approximate size: 18'-0"x2'-0"x0'-7.5" thick(2nd Floor)A'Level |
Rs. 0.00 | 0.00% | Rs. 0.00 |
1 nos | Repairing of window projections including apply zuba 16/123 anti rust on exposed rusted steel bars after removal of rust using steel wire brush, fixing of chicken wire mesh where required, apply 1:4 cement sand mortar of required depth to match existing thickness or any chemical required to secure projections complete. Approximate size: 8'-6"x2'-0"x0'-7.5" thick (1st Floor) A'Level |
Rs. 0.00 | 0.00% | Rs. 0.00 |
2 nos | Repairing of window projections including apply zuba 16/123 anti rust on exposed rusted steel bars after removal of rust using steel wire brush, fixing of chicken wire mesh where required, apply 1:4 cement sand mortar of required depth to match existing thickness or any chemical required to secure projections complete. Approximate size: 3'-6"x2'-0"x0'-7.5" thick (2nd Floor)Sci Block |
Rs. 0.00 | 0.00% | Rs. 0.00 |
1 nos | Repairing of window projections including apply zuba 16/123 anti rust on exposed rusted steel bars after removal of rust using steel wire brush, fixing of chicken wire mesh where required, apply 1:4 cement sand mortar of required depth to match existing thickness or any chemical required to secure projections complete. Approximate size: 7'-6"x2'-0"x0'-7.5" thick (ground Floor)A' Level |
Rs. 0.00 | 0.00% | Rs. 0.00 |
18 Nos | Demolishing of defective column with care (If Necessary )after removing of cladding and shifting of debris from site and Providing 1:2:4 ratio including fixing and removal of water tight shuttering apply zuba 16/123 on rusted steel bars which are exposed including plastering of column using 1:4 unto required depth. Complete in all aspects as per directed by engineer approx column size 2'-6"x 3'-6" A' Level |
Rs. 0.00 | 0.00% | Rs. 0.00 |
12 Nos | Demolishing of defective column with care (If Necessary )after removing of cladding and shifting of debris from site and Providing 1:2:4 ratio including fixing and removal of water tight shuttering apply zuba 16/123 on rusted steel bars which are exposed including plastering of column using 1:4 unto required depth. Complete in all aspects as per directed by engineer approx column size 2'-6"x 3'-6" Science block |
Rs. 0.00 | 0.00% | Rs. 0.00 |