1st Floor, Noor Square, Opp. Askari Park, Old Sabzi Mandi, Karachi
Quote Number | QUO-397 |
Quote Date | April 24, 2024 |
Total | Rs. 0.00 |
-
Civil & Water Proofing of A-Level Block & Principal Residence
Hrs/Qty | Service | Rate/Price | Adjust | Sub Total |
---|---|---|---|---|
17323 Sq | Water Proofing ( A-Level) "Providing and laying of water proofing & Heat proofing solution (Aquafin , Zahabiya , BMT , Basf or approved equivalant including cutting/making of grooves approx. 0.5 to .75"" deep in parapet wall for inserting water proofing membrane and also finish same grooves with waterproof chemical (Zahabiya, aquafin, fospak,BMT or approved equivalent). Water proofing must be done upto approx. 8"" height on parapet wall. Providing and laying of cantstrip approx. 0'-6"" to 0'-8"" with ratio 1:2:4 and use synthetic fiber in concrete (Recorn, Matrix or approved equivalent) on the edge of prapet wall, columns, air vents, over head water tank and concrete pads and at all floor wall junction as per site requirements before making of Cantstrip the surface need to be treated by tucking and grinding complete in all respect as directed by Client/Engineer. |
Rs. 0.00 | 0.00% | Rs. 0.00 |
3550 Sqf | Water Proofing Principal's Residence "Providing and laying of water proofing & Heat proofing solution (Aquafin , Zahabiya , BMT , Basf or approved equivalant including cutting/making of grooves approx. 0.5 to .75"" deep in parapet wall for inserting water proofing membrane and also finish same grooves with waterproof chemical (Zahabiya, aquafin, fospak,BMT or approved equivalent). Water proofing must be done upto approx. 8"" height on parapet wall. Providing and laying of cantstrip approx. 0'-6"" to 0'-8"" with ratio 1:2:4 and use synthetic fiber in concrete (Recorn, Matrix or approved equivalent) on the edge of prapet wall, columns, air vents, over head water tank and concrete pads and at all floor wall junction as per site requirements before making of Cantstrip the surface need to be treated by tucking and grinding complete in all respect as directed by Client/Engineer. |
Rs. 0.00 | 0.00% | Rs. 0.00 |
100 Sqft | Civil Work Principal's Residence "Removing, cutting and chiseling of cracked parapet wall and short column embadded in parapet wall with care including shifting of debris from school premises through trucks as per instruction of school management. Providing and applying plaster (1/2"", 3/4"") thick upto required depth using 1:4 cement sand ratio on parapet wall including application of anti rust chemicals on exposed steels, expanded metal(mesh) at junction wherever else is required with SBR as per standard ratio by 1 part of SBR :1 part of water :4 part of cement by volume with smooth finish, curing etc. Demolishing of defective columns with care and shifting of debris from site through truck. Providing and applying of concrete 1:2:4 ratio including fixing and removal of water tight shuttering, apply zuba 16/123 anti rust on exposed rusted steel bars after removal of rust using steel wire brush and also use in concrete, plastering complete. |
Rs. 0.00 | 0.00% | Rs. 0.00 |
00 | Concrete Pads A' Level Approximate size :- 2'-3" x0'-9"x3'-0" Providing and making of Concrete pads for water supply or gas lines approx. size of one pad (12" x 10" x 8") of Solid block on roof with smooth finish Plaster 1: 4, curing etc, slope of pads to be made as per existing site conditions. Same as made on Auditorium roof complete in all aspects as directed by engineer-In-charge |
Rs. 0.00 | 0.00% | Rs. 0.00 |
Sub Total | Rs. 0.00 |
Tax | Rs. 0.00 |
Total | Rs. 0.00 |